Queen's Hall Technical Spec

TECHNICAL SPECIFICATIONS

354 seat auditorium (254 stalls, 100 balcony) with end stage usually played as traditional proscenium theatre; First three rows (44 seats) demountable.

Dimensions

Stage Dimensions 

Side Elevation

Proscenium width 9040mm, 29’8”
Proscenium line to rear wall 7560mm, 24’9”       
Forestage to rear wall  8660mm, 28’5”
Grid height  c 12000mm
Proscenium height  c 7000mm


Flying

Flying System

11 sets of double purchase counterweighted bars
15 sets of 3 line hemp bars
Bar length c 9050mm
Bar operated from fly floor stage right
5 of the c/w bars ( no 2, 4, 6, 8 & 9) are permanently assigned as LX bars and are non negotiable

Stage Management

Sound Logic Intercom, cue lights, belt pack ring, show relay/tannoy system.
Sound and light operated from box (rear of circle).

Lighting

Light Bar Positions

Cable remote
ETC Congo Jnr with v5.1 software
82 @ 2kw, 8 @ 5kw dimmers
28 @ Lito 1kw Fresnels
9 @ Selecon HP 1200 Fresnels
6 @ ETC S4 Zoom 25/50 Profiles
3 @ Strand SL 23/50 Profiles
3 @ Strand SL 15/30 Profiles
2 @ Selecon Pacific 23/50 Cool Beam Profiles
14 @ 1kw par cans
6 @ ETC S4 Zoom 15/30 Profiles (permanently rigged FOH Bridge)
4 @ Strand SL 15/32 Profiles (permanently rigged FOH Bridge)
2 @ Strand SL 23/50 Profiles (permanently rigged FOH Booms)
4 @ Lito Quad Eye Floods (c/frames 53cm x 39cm) Hard wired to LX5 (c/w9)
1 @ CSI Follow Spot
Colour stock (limited) – Lee, Colortran

Lanterns marked as permanently rigged in FOH positions are not available for use onstage.

Please Note that there is no advance lighting bar position


Sound

Tascam MD 350 Minidisk Player/Recorder
Sony Minidisk player/Recorder
DN-C635 pro CD
Numark twin CD Player
Soundcraft LX7 Mixer 24/4/2
2 X Dbx stereo 15 band EQ (inserted on monitor sends)          
4 @ Tannoy V12 FOH speakers
4 @ 15” Dual concentric Stage Monitors
2 @ AKG D310 mics
3 @ Shure SM57 mics
5 @ Shure SM58 mics
2 @ Sennheiser Evolution 664 Condenser mics
2 @ Sennheiser 602 mics
2 @ Behringer B5 Condenser mics
2 @ Behringer C2 Stereo pair Condenser mics
2 @ Evolution 300 series radio mic packs
2 @ Lavalier tie clip mics
1 @ Evolution 300 series Handheld mic 
10 @ boom stands

Dressing Rooms

Two rooms accommodating a total of 14. Three showers & toilets.
Overspill dressing room can be arranged with advance notice.

PLEASE NOTE

Get Out must commence within 30 minutes of final performance.

Please direct any technical enquiries to Alex Perry, Senior Technician.

DWG / JPEG Versions.zip

PDF Versions
Flying System
Stage Dimensions
Side Elevations
Lighting Bar Positions